AWS 90.SI

High insulation thermal break window system, with total face width of 90mm.

The extended thermal insulation zone with the specially designed thermal break chambers with foam ensure top energy-saving performance and minimise heat loss. This system’s energy profiles is complemented by top sealing performance, featuring high wind pressure resistance, air and water permeability; it is an excellent solution for upgrading a place to Passive House.

  • Total face width 112mm
  • Double or triple glass pane option (up to68 mm)
  • Extended thermal insulation zone with thermal breaks & chambers with foam
  • SCHÜCO SimplySmart hidden mechanism applicatino up to 250 kg

Technical Characteristics

Dimensions

Frame profile depth: 90 mm
Frame face width: 56 mm
Maximum glass thickness: 28-63mm casement 28-68 mm / sash mm

Sash profile depth: 100 mm
Sash face width: 83 mm

Description: RAL 9016 STRUCTURA
Code: YA316F
Technology: Interpon D2525
Collection: Structura
Company: AkzoNobel

Description: GRAZALEMA 2525
Code: YW266F
Technology: Interpon D2525
Collection: Futura 2014-2017
Company: AkzoNobel

Description: GRIS 2500 SABLE
Code: YW358F
Technology: Interpon D2525
Collection: Futura 2014-2017
Company: AkzoNobel

Description: RAL 7016 STRUCTURA
Code: YL316F
Technology: Interpon D2525
Collection: Structura
Company: AkzoNobel

Description: BLUE 2600 SABLE
Code: YW361F
Technology: Interpon D2525
Collection: Futura 2014-2017
Company: AkzoNobel

Description: RAL 8014 STRUCTURA
Code: YM314F
Technology: Interpon D2525
Collection: Structura
Company: AkzoNobel

Schüco TipTronic installation option and sheet weight 160kg

Mechanism: SCHÜCO Simply Smart mechanism up to 250kg

Extended thermal insulation zone with reinforced thermal breaks and foam at the glass chambers

EPDM sealing gaskets

Profiles have straight form

Uw 0.8W/(m2K) option with the use of triple glass pane and thermal gaps.

Thermal Insulation: Up to Uf 0,71 W/m2K in accordance with DIN EN ISO 10077-2

Soundproofing up to Rw=47dB in accordance with DIN EN ISO 140-3

Burglar resistance up to RC3 in accordance with DIN V ENV 1627

Air permeability in accordance with DIN EN 12207 Class: 4

Water permeability in accordance with DIN EN 12208 Class: 9a

Wind pressure resistance in accordance with DIN EN 12210: Class: C5 / B5

Mechanical strength in accordance with DIN EN 13115 Class: 4

Functionality over time in accordance with DIN EN 12400 Class: 3

Discover more